The Postgraduate Mechanical Engineering Building consists of 4 floors that function as teaching and learning activities. By increasing the floor to 6 floors and adding a canteen area as a supporting facility, the building is planned to use a 12-meter pre-stressed beam on the 4th floor of the meeting hall so that the supporting column in the middle of the 3rd floor can be eliminated. This plan aims to design and analyze structural elements including prestressed beams and their implementation methods using a special moment-bearing frame system with earthquake resistance according to the latest structural planning rules. The results of the post-tensile prestress planning analysis indicated that the prestressed beams experienced a friction loss of 6.37%, anchorage of 5.04%, creep of 4.99%, shrinkage of 0.07%, and steel relaxation of 9.07%. The total prestress force loss obtained was 25.53%. with an effective prestress force of 3000 kN can work on the structure.